ACEINNA Expands AMR Based Current Sensor Family


ACEINNA announced that their industry leading MCx1101 family of Current Sensors now supports 3.3 volt applications. These highly accurate, wide bandwidth AMR-based current sensors are now available for a wide range of ADC and microprocessor based power systems and applications. 

Units are now available for sampling and volume shipments.

“Our integrated, AMR based Current Sensor family provides the best performance for the price in the industry,” says Khagendra Thapa, VP Current Sensor Product for ACEINNA. “Unlike other AMR based current sensing solutions on the market that require an extensive and time consuming integration to make them work, ours are plug and play.”

The MCx1101 are fully integrated, bi-directional current sensors that offer much higher DC accuracy and dynamic range compared with alternative solutions. For example, the ±20A version has a typical accuracy of ±0.6% and are guaranteed to achieve an accuracy of ±2.0% (max) at 85°C. These new current sensors are in an industry standard SOIC-16 package with a low impedance (0.9 milli-ohm) current path and are certified by UL/IEC/EN for isolated applications.

These new current sensors also guarantee an offset of ±60mA, or ±0.3% of FSR (max) over temperature, which means that high accuracy can be achieved over a roughly 10:1 range of currents providing significant improvement in dynamic range vs. leading Hall-sensor-based devices.

These devices deliver a unique combination of high accuracy, 1.5MHz signal bandwidth with industry benchmark phase shift vs. frequency, fast output step response and 4.8kV isolation making them ideal for current sensing in fast current control loops and protection for high performance power supplies, inverters and motor control applications. 

The fast response and high bandwidth of the MCx1101 is also ideal for fast switching SiC and GaN based power stages enabling power system designers to make use of the higher speeds and smaller components enabled by wide band-gap switches.  Output step response time is 0.3us. The MCx1101 also provides an integrated over current detection flag to help implement OCD (Over Current Detection) required in modern power systems. Over current detection response time is fast 0.2us. 

The family includes ±50, ±20, and ±5A ranges, and is offered in both fixed gain (MCA1101) and ratiometric gain (MCR1101) versions.

 



July 24, 2019


Topic Area: Press Release


Recent Posts

Sustainability as a Baseline in Healthcare Facilities

Hospitals can balance costs, build resilience and learn from global models for sustainable design to further their green goals.


Penobscot Valley Hospital Reports Data Security Incident

It immediately implemented its incident response procedures, took steps to secure systems and hired third-party forensic specialists to assist with an investigation.


Ballad Health Acquires Land for Future Unicoi County Hospital

The new hospital is expected to feature an emergency department, 10 inpatient beds and outpatient services.


Why Healthcare Facilities Management Is Critical to Patient Safety 

Hospitals and other healthcare facilities rely on much more than doctors and nurses to keep patients safe.


Brookdale Senior Living Announces Acquisition of the Brookdale Galleria Community

The 244-unit independent living and assisted living community is located directly adjacent to The Galleria shopping and entertainment complex.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.