ASCO redefines mobile notifications with 5170 Quad-Ethernet Module


ASCO Power Technologies today announced new capabilities for its ASCO® 5170 Quad-Ethernet Module, which expands the type of information facility managers can access through mobile devices about on-site power systems.

The ASCO 5170 Quad-Ethernet Module is a proactive connectivity interface for communicating information on real-time power monitoring, control and historical insight of automatic transfer switches, engine-generators and their loads, and a utility power source. It expands the boundaries of information on critical power events and alarms that is available to facility managers when they are offsite and have access only to mobile devices.

"Traditionally, email or text notifications would only advise when the utility source would fail and a signal was sent to start the on-site power system, but not report on the result of that action," said Mario Ibrahim, director of ASCO Products and Innovation. "Now, it also notifies exactly what happened--whether on-site power started and powered up to feed loads," he said. "It's positive information that closes the loop and provides peace of mind."

Facility managers can access the information on smart phones, tablets, PCs and other mobile devices anywhere, anytime. A built-in HTML5 web page application displays data in whatever form users want. The page adjusts automatically to any screen size as well as to portrait and landscape perspectives. 

Open Modbus and SNMP capabilities provide facility managers and IT personnel, respectively, the flexibility to aggregate and present raw data in whatever format they want via the ASCO Critical Power Management System (CPMS), conventional building monitoring system (BMS), data center infrastructure management (DCIM) platform, or a network operations center (NOC). Both Modbus and SNMP operate simultaneously.

The ASCO 5170 enables total remote monitoring, control, transfer sequences, and data retrieval for testing, or otherwise exercising, on-site power.

Connectivity for monitoring allows tracking the state of the power system in real time, active timers, historical logs, transfer statistics and past activity. Users also can monitor such configured settings as pickups, drop outs, time delays and enabled features.

Connectivity for control permits remote transfer for testing and exercising. Active transfer time delays can be bypassed on demand. 

Connectivity for data retrieval using industry standard protocols and a built-in, four-port Ethernet switch optimizes connectivity options and flexibility. It accommodates multiple communication paths, thus practically eliminating the need to disconnect one path to connect another and the necessity of opening an automatic transfer door to manually make the disconnection/connection, or to download data. The ASCO 5170 module sustains 16 simultaneous data streams.

Advanced AES 128-bit encryption safely secures monitoring and control functions from unauthorized access. Event logs can be printed in PDF format. The ASCO 5170 can be an accessory (Accessory 72EE2) on new ASCO 7000 Series and 4000 Series Automatic Transfer Switches, and can be field retrofitted to installed systems.

For more information on the ASCO 5170 Quad-Ethernet Module, visit www.ascoapu.com.



March 2, 2016


Topic Area: Press Release


Recent Posts

Must Know Recalls of 2025

For the safety of our readers, Healthcare Facilities Today has closely followed all recall notices related to the industry.


Sustainability as a Baseline in Healthcare Facilities

Hospitals can balance costs, build resilience and learn from global models for sustainable design to further their green goals.


Comanche County Memorial Hospital and Southwestern Medical Center Join to Form Partnership

The partnership will go into effect by the end of December 2025.


Choosing a Disinfectant That Kills Biofilm

Bacteria form biofilms in pipes from which cells can be released during sink use and spread outside the drains in droplets or as aerosols.


Third-Party Data Breach Case Underscores Need for Cyber Risk Management

Plaintiffs alleged negligence in safeguarding patient data; defendants denied wrongdoing but settled to avoid litigation costs.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.