CINTEC Technology announces new dissipative anchor

June 28, 2018

CINTEC International, a provide of the field of structural masonry retrofit strengthening, repair, and preservation, announces that it has developed a new type of dissipative wall anchor. The new anchor solves the issues of how to protect heritage buildings in some of the most earthquake-prone parts of the world.

This new product is an innovative dissipative anchor designed for use with Cintec’s proven wall anchor system.

“We believe that this anchor is a major breakthrough in further protecting the world’s iconic buildings, especially in areas of high seismic activity,” said Peter James, Managing Director of Cintec International. “This anchor has been four years in development within the NIKER program. It has undergone extensive testing at Bath University, and in Italy.”

The standard Cintec anchor system consists of a stainless steel anchor body encapsulated in a fabric sock. Diamond holes are drilled into the building and each anchor is placed in a hole. A specialized grout in pumped to the far end of the anchor, filling from back to front until the entire sock is inflated like a balloon. After the anchor has been inflated, the walls have been securely strengthened without affecting the outside appearance of the building.

For buildings subject to regular earthquake activity, there is a possibility of pull-out damage at the anchorage head. The new anchor solves this problem by allowing for small amounts of movement through a sliding mechanism.

The Cintec dissipative anchor consists of a set of stainless steel plates to which four bolts apply pressure, creating friction to an adjustable degree. There are built-in stops to restrict the sliding motion, and connectors that link to Cintec’s standard anchor rods. The anchor allows a controlled and repairable drift for the walls, managing the amount of seismic energy fed into the structure and therefore minimizing damage to the building.

The development of this anchor resulted from Cintec’s involvement with the European NIKER project. In 2011, Cintec was chosen as the only British commercial company to actively participate in this project, the aim of which was to protect the artistic value of cultural heritage sites from earthquake-induced damage. Cintec has been working in collaboration with the University of Bath to create and test the dissipative anchor since then, and has now patented the finished product.

Cintec anchors have been used to strengthen and restore historically significant structures around the globe, including Egypt’s pyramids, Windsor Castle, and even the White House.

For more information, visit www.cintec.com.       

 

See the latest posts on our homepage


Share

Topic Area: Press Release


Recent Posts
Recent Posts
Focus: Infection Control

Agencies investigating Legionnaires' case at McLaren Flint


Hospital officials acknowledging that a patient may have acquired the disease at the facility

5/24/2019

Focus: Infection Control

Study: Outside temperature impacts pathogens in climate-controlled ICUs


The outside temperature can influence the indoor temperature

5/24/2019

Security hired for Manitoba healthcare facilities after city bills for police time


Province announces two guards will be on staff at all times

5/24/2019

Blog

When to consolidate clinical testing (core) laboratories.


Increasingly, customers of clinical testing labs want a one-stop shop, particularly as large healthcare systems acquire smaller, more specialized independent practices

5/24/2019

'Best Places to Work' in healthcare named


Modern Healthcare shares alphabetical list of winners

5/24/2019





Post Comment




FREE
NEWSLETTER

News & Updates • Webcast Alerts • Building Technologies

All fields are required.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.