Handheld vane anemometer/psychrometer offers 8-in-1 functionality


 

(New York, NY)  The new Mini-Anemometer/Psychrometer with CFM/CMM & Enthalpy (DAF3009) from General Tools & Instruments (General®) is ideal for HVACR technicians and contractors. It offers the ability to measure eight HVACR-related parameters in one handheld device that is small and light enough for one-handed operation.

The DAF3009 can measure all parameters associated with installing, testing and fine-tuning the performance of an HVACR system:

· Airflow Volume (in CFM or CMM)

· Air Speed (in ft/min, m/sec, km/hr, mph or knots)

· Enthalpy (in BTU/lb or kJ/kg)

· Ambient Temperature

· Dew Point Temperature

· Wet Bulb Temperature

· Wind Chill Index

· Relative Humidity

The instrument not only can measure air speed and airflow volume, but also can track and calculate the maximum, minimum and average values recorded over a measurement “session.” A session begins when the device is powered on and ends five minutes after the final measurement is made (when the Auto Power Off function activates). This capability is helpful for a variety of purposes, such as determining the fastest and slowest fans in a group or the average of a group of fans.

The DAF3009 also features a large backlit dual-readout LCD, a vane and sensor cap and a tripod mount. It offers the following measurement ranges and accuracies.

· Airflow Volume: 0 to 591,000 CFM (0 to 16,740 CMM); +/-3% typical

· Air Speed: 80 to 5910 ft/min (0.4 to 30 m/s); +/-3% typical

· Enthalpy: -8 to 318 BTU/lb. (-19 to 740 kJ/kg)

· Ambient Temperature: 32° to 122°F (0° to 50°C) ; +/-1.8°F (1°C) typical

· Dew Point: -67° to 122°F (-55° to 50°C)

· Wet Bulb: -31° to 122°F (-35° to 50°C)

· Relative Humidity: 0 to 100%; +/-3% typical

 

 



December 8, 2014


Topic Area: Press Release


Recent Posts

Seeking Standards for Microbial Loads in Healthcare Facilities

Why is there no binding standard for the acceptable microbial load on surfaces or in the air in hospitals?


UCR Health Unveils Plans for Major Expansion

The vision for the site will include an outpatient diagnostic center and possible future expansion.


High-Performance Windows Support Safety at UW Medicine's New Behavioral Health Center

Case study: Engineered for strength, quiet and daylight, the chosen windows help create a safe, calming and energy-efficient environment for patients and providers.


Central Maine Healthcare Dealing with IT System Outage

The organization identified unusual activity within their computer software, prompting them to secure and shut off all IT systems.


Kaiser Permanente Opens Newly Expanded Everett Medical Center

The facility offers primary care and pediatric care and has specialty care departments.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.