MEMSIC Launches New MDP200 Pressure Sensor for Medical, Automotive and Industrial Applications


MEMSIC Inc., a leading sensing solutions provider, today announced the launch of its MDP200 Bi-Directional Differential Pressure Sensor for CPAP, breath detection, room pressure, damper control, flow hood, fume hood, filter monitoring and other applications where ultra-low differential pressure performance is required.

Currently sampling, this industry leading pressure sensor will be shipping in commercial quantities by the end of this year.

Leveraging its highly successful thermal accelerometer technology and experience in consumer electronics, MEMSIC will be offering a high-performance differential pressure sensor for medical, HVAC and other applications where competitively priced, highly reliable and ultra-low pressure performance is required.

The new MDP200 new pressure sensor is based upon MEMSIC’s highly advanced and successful MEMS thermal accelerometer platform, with hundreds of millions of units successfully shipped into a diverse variety of real world automotive and consumer applications. This ultra-sensitive MEMs thermal technology enables the new MDP200 to detect minute changes in flow induced by differential pressure.  The suspended bridge microstructure inside the MDP200 allows it to reliably detect pressure changes from a range of 0.016 Pascal to 500 Pascal.    

“No diaphragm type sensor can achieve this level of performance,” says Ohlan Silpachai, Flow Product Manager at MEMSIC. “We compared our MDP200 against a class leading competitor differential pressure sensor with a 0 to 0.1 inch water column (25 Pascal) output range.  In this head to head test, Memsic’s MDP200 demonstrated a superior signal to noise ratio at signal levels below 1 Pa, while offering a full scale range of 20x higher (MDP200 is calibrated at +/-500 Pa).  The integrated electronics within the sensor chip allows a 16 bit digital I2C output at an update rate of less than 7 ms.” 

More details and the data sheet are available athttp://www.memsic.com/flow-sensors/MDP200



July 13, 2017


Topic Area: Press Release


Recent Posts

Disinfectant Contact Time: The Case for Biofilm Disruption

Contact time, while essential for compliance, does not reliably predict microbial reduction on actual healthcare surfaces.


Rethinking How Healthcare Facilities Fund Construction Projects

Rising costs and competing priorities are driving healthcare organizations to explore new financing arrangements and construction strategies.


Putting Trauma-Informed Design into Practice

Arnold's Place demonstrates how design choices can promote dignity and a sense of control for those experiencing homelessness.


Harris Health to Build New Freestanding Cancer Center

The center is planned to open in 2029, following the opening of the new O'Quinn Hospital along the North Loop at Lockwood.


Inland Empire Health Plan Opens Expanded San Bernardino Community Wellness Center

The new 33,000-square-foot center is nearly three times the size of the original location off Second Street.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.