MEMSIC Launches New MDP200 Pressure Sensor for Medical, Automotive and Industrial Applications


MEMSIC Inc., a leading sensing solutions provider, today announced the launch of its MDP200 Bi-Directional Differential Pressure Sensor for CPAP, breath detection, room pressure, damper control, flow hood, fume hood, filter monitoring and other applications where ultra-low differential pressure performance is required.

Currently sampling, this industry leading pressure sensor will be shipping in commercial quantities by the end of this year.

Leveraging its highly successful thermal accelerometer technology and experience in consumer electronics, MEMSIC will be offering a high-performance differential pressure sensor for medical, HVAC and other applications where competitively priced, highly reliable and ultra-low pressure performance is required.

The new MDP200 new pressure sensor is based upon MEMSIC’s highly advanced and successful MEMS thermal accelerometer platform, with hundreds of millions of units successfully shipped into a diverse variety of real world automotive and consumer applications. This ultra-sensitive MEMs thermal technology enables the new MDP200 to detect minute changes in flow induced by differential pressure.  The suspended bridge microstructure inside the MDP200 allows it to reliably detect pressure changes from a range of 0.016 Pascal to 500 Pascal.    

“No diaphragm type sensor can achieve this level of performance,” says Ohlan Silpachai, Flow Product Manager at MEMSIC. “We compared our MDP200 against a class leading competitor differential pressure sensor with a 0 to 0.1 inch water column (25 Pascal) output range.  In this head to head test, Memsic’s MDP200 demonstrated a superior signal to noise ratio at signal levels below 1 Pa, while offering a full scale range of 20x higher (MDP200 is calibrated at +/-500 Pa).  The integrated electronics within the sensor chip allows a 16 bit digital I2C output at an update rate of less than 7 ms.” 

More details and the data sheet are available athttp://www.memsic.com/flow-sensors/MDP200



July 13, 2017


Topic Area: Press Release


Recent Posts

Mattresses Require Strict Care to Prevent Spread of Infections

Poor cleaning and disinfection techniques contribute to the persistent contamination of patient mattresses.


Gardner Health Services Opens Alum Rock Health Center

The 10,080-square-foot facility provides essential medical, dental, mental and chiropractic services to the Mayfair and East San José neighborhoods.


The Children's Center of Hamden Reports Data Security Incident

The incident was detected on December 28, 2024.


Designing for Senior Care Communities Means Designing for Everyone

No spaces can be designed for just one person, designers need to think about everyone who will occupy the space.


Harlem Hospital Legionnaires' Outbreak Highlights Cooling Tower Risks

Seven deaths linked to the cooling towers underscore the need for stricter water system monitoring and preventive maintenance in healthcare settings.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.