New Ametherm ACCU-Curve series of interchangeable thermistors features tight tolerances of ± 0.2 °c for high-accuracy temperature measurement


Ametherm introduced a new series of interchangeable thermistors that provide long-term stability and reliability for high-accuracy temperature sensing, control, and compensation. ACCU-Curve series thermistors are available in a wide range of resistance values, with tight tolerances of ± 0.2 °C between 0 °C and 70 °C and fast thermal response times. 

Providing designers with faster, less-expensive alternatives to RTD probes and thermocouples — without compromising on accuracy — ACCU-Curve series devices deliver the tight tolerances required for temperature measurement in critical medical instrumentation, and they can be potted in a variety of housings for temperature compensation circuits in industrial and automotive applications.

Offering diameters of 2.4 mm and 32 AWG tinned-copper leads, the epoxy-coated thermistors are available in four resistance values at 25 °C — 2.252 kΩ, 3.0 kΩ, 5.0 kΩ, and 10 kΩ — with a dissipation constant of 1 mW/°C and thermal time constant of 10 s. 

The devices are available direct or through distributors such as Digi-Key and Mouser. Samples and production quantities of the thermistors are available now, with factory lead times of 12 weeks. Volume pricing for U.S. delivery starts at $1.25 per piece.

For more information or to request a sample, visit www.ametherm.com.



October 29, 2015


Topic Area: Press Release


Recent Posts

Mature Dry Surface Biofilm Presents a Problem for Candida Auris

Multiple methods are described in the literature, but no consensus has been reached for disinfection efficacy tests against biofilms.


Sutter Health's Arden Care Center Officially Opens

With an adaptive reuse of an underutilized office building, the 70,000 square-foot facility was renovated to meet current healthcare standards.


Insight Hospital and Medical Center Falls to Data Breach

The investigation determined that an unauthorized individual accessed the network between August 22, 2025, and September 11, 2025.


The High Cost of Healthcare Violence

As workplace violence increases, healthcare facilities face mounting financial and operational disruptions- prompting legislative action.


EVS Teams Can Improve Patient Experience in Emergency Departments

A report confirmed that cleanliness of the ED was the third most impactful element on patient experience surveys.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.