New NAIMA Guide recommends installation methods for insulating chilled water systems with mineral fiber pipe insulation


The North American Insulation Manufacturers Association (NAIMA) has issued a new publication entitled Guide to Insulating Chilled Water Piping Systems With Mineral Fiber Pipe Insulation. Developed for professional insulation contractors, this comprehensive 36-page guide recommends methods for insulating chilled water piping systems using a vapor sealed mineral fiber pipe insulation.

32-page guide was developed for professional insulation contractors

"Insulation systems are critical to limiting heat losses and preventing condensation on pipe surfaces operating from 33 degrees F to 60 degrees F (0.5 degrees C to 15.6 degrees C) within conditioned spaces in commercial and institutional buildings," explained Charles Cottrell, Vice President Technical Services for  NAIMA.  "When poorly applied, however, an insulation system can compromise insulation effectiveness. NAIMA developed this step-by-step guide for applying vapor sealed mineral fiber pipe insulation, which when installed according to the guide's recommendations, can effectively control condensation, help extend the life of the insulation system, and save energy."

The Guide addresses the installation of standard ASJ jacketed pipe insulation used in the field and presents recommendations based on reliable engineering principles and research, as well as consultation with manufacturers, contractors and industry experts. It details insulation application on straight pipe; on pipe system fittings including flanges, couplings, elbows, tees, and valves; and on 45- and 90-degree elbows.  Also included are details on vapor dams, pipe supports and field-applied jackets. Accompanying each application description is a full-color illustration demonstrating the installation method discussed.

 Other sections in the guide include performance criteria, a guide specification, installation checklist and an extensive appendix outlining a wide range of information resources and references. 

To download a free copy of the Guide to insulating Chilled Water Piping Systems with Mineral Fiber Pipe Insulation, visit www.naima.org.



July 23, 2015


Topic Area: Press Release


Recent Posts

Site Selection Mistakes: What Not To Do

Healthcare providers that treat site selection as a strategic decision, not a simple real estate deal, will be positioned for long-term success.


High-Performance EFCO Systems Shape MUSC's New Black River Medical Center

Case study: A sweeping curved-glass entrance, impact-resistant envelope and energy-efficient fenestration support a sustainable, resilient design for one of South Carolina’s newest rural hospitals.


Heritage Valley Health System to Officially Affiliate with Alleghany Health Network

With the affiliation now complete, Heritage Valley Beaver and Heritage Valley Sewickley will be rebranded.


The Impact of Acoustics on Patient Privacy

As healthcare facilities evolve toward more open and flexible care environments, acoustic privacy has become essential.


Texas Behavioral Health Center in Dallas Opens with Ribon-Cutting Ceremony

The 456,265-square-foot facility offers a variety of therapeutic, recreational and social spaces that prepare patients for life outside the hospital.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.