North Carolina Energy Conservation Code Goes into Effect


 North Carolina’s 2018 State Building Code went into effect January 1, 2019 complete with an updated Energy Conservation Code for Commercial Buildings. The new code includes the 2015 IECC©along with North Carolina specific amendments that need to be applied to any building submitted for permitting.

With the adoption of the 2018 North Carolina State Building Code for Energy Conservation (NCECC), North Carolina continues to increase the energy efficiency of its new commercial buildings, providing lower energy operating costs to building owners and managers.

Harold Jepsen, Vice President of Standards and Industry, Building Control Systems at Legrand, North & Central America, has outlined the biggest lighting control changes in the upcoming code updates.
 

Lighting Control Provisions Changes

  • All commercial buildings must comply with automatic shut off requirements, regardless of square footage. Buildings under 5,000 square feet are no longer exempt from this provision as in the prior code. 
     
  • Occupancy sensor control requirements used for automatic lighting shut off have been expanded to include rooms defined as being used for multipurpose, copy, print, mechanical, electrical, lounges, computer server, and warehouse spaces. The updated code also includes the eight defined uses already existing under the 2012 NCECC.
     
  • Warehouse aisles and open areas must reduce lighting by at least 50 percent when not occupied. This will increase energy savings during normal warehouse operating hours when there is no activity in individual storage aisles and open areas by reducing, or completely turning off unneeded lighting.
     
  • Hotel and motel guestrooms must automatically turn off lighting and switch receptacle, so lighting is not left on when guests leave the room.

Additional Code Changes

 Outside of lighting controls, the 2018 NCECC has also adopted changes for lighting power allowances and efficiency package options, including:

  • Revised lighting power allowance tables that reduce lighting power density in many common spaces from five to 12 percent.
  • Added lighting measures for the Additional Efficiency Package Options.
  • Revised lighting control system functional testing requirements.

Solutions & Resources

Compliance design examples for the new code are offered for free at Legrand. Visitors can find assistance in selecting appropriate controls and code compliant sequence of operations for many typical commercial building space types. Resources include:

 



February 1, 2019


Topic Area: Press Release


Recent Posts

Healthcare Real Estate: Responding to Shifting Patient Demands

To compete in a changing landscape, healthcare organizations must turn their real estate from a cost center into a competitive advantage.


Over 40% of Workers Impacted by Seasonal Depression

Seasonal changes can have an impact on work performance.


Archer Property Partners Acquires Medical Office Building Near Tri-City Hospital

Archer plans a $2.5 million capital improvement program to fully modernize and reposition the asset as one of North County’s premier medical office destinations.


The OR HVAC Puzzle: Why Individual Systems Are on the Rise

Extra penetrations, tight clearances and strict humidity needs—design experts explain what it really takes to plan dedicated units for each operating room.


Sutter Health Announces Plans for New Santa Clara Medical Center

Sutter projects the medical center will open in late 2031.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.