OSHA Addresses N95 Respirator Decontamination


The Occupational Safety and Health Administration (OSHA) issued enforcement guidance allowing the decontamination and reuse of N95 respirators during the COVID-19 pandemic on a case-by-case basis. The interim guidance to the agency’s Compliance Safety and Health Officers (CSHO) allows the reuse, in certain circumstances, of filtering facepiece respirators (FFR) decontaminated using methods that have shown promise in limited research.

OSHA Guidance for Employers

According to OSHA, employers should:

  • Make a good-faith effort to provide and ensure workers use the most appropriate respiratory protection available for expected workplace hazards;

  • Ensure decontamination is performed according to CDC guidance;

  • Ensure employees perform a user seal-check each time they don a respirator and not permit use of a respirator on which the user cannot perform a successful user seal-check;

  • Train employees to follow appropriate precautionary measures detailed in the CDC’s guidance before using a decontaminated FFR;

  • Train employees using decontaminated respirators to understand that if the structural and functional integrity of any part of the respirator is compromised, it should not be used for respiratory protection—an inability to achieve a successful user seal-check could be an indicator that the integrity of the respirator is compromised;

  • Visually inspect, or ensure that workers visually inspect, FFRs to determine if the structural and functional integrity of the respirators has been compromised—components such as the straps, nose bridge, and nose foam material may degrade over time or as a result of decontamination and affect the quality of the respirators’ fit and seal; and

  • Train employees on the procedures for properly donning and doffing respirators to prevent self-contamination.

If employers have no manufacturer or third-party guidance or procedures for specific decontamination methods, then workers should avoid using decontaminated FFRs when performing aerosol-generating procedures on patients who are or may be infected with SARS-CoV-2. Aerosol-generating procedures include bronchoscopy, cardiopulmonary resuscitation, intubation and extubation, nebulizer therapy, and sputum induction. Decontamination may degrade FFR performance, and decontaminated respirators may not provide the level of protection needed during such procedures.

OSHA instructed CSHOs to exercise discretion in issuing citations if FFRs are decontaminated and reused in cases when:

  • Other feasible measures, such as using partitions, restricted access, the cohorting of patients, other engineering controls, work practices, or administrative controls to reduce the need for respiratory protection, were implemented to protect employees;

  • The employer has made a good-faith effort to obtain other alternative FFRs, reusable elastomeric respirators, or powered air-purifying respirators (PAPRs), including NIOSH-certified equipment or previously NIOSH-certified equipment past its manufacturer’s recommended shelf life;

  • The employer has monitored its supply of FFRs, prioritized their use according to CDC guidance, and controlled the number of times a respirator is decontaminated before issuing a new one, given supply-level and burn-rate considerations; and

  • Surgical masks and eye protection such as face shields and goggles were provided as an interim measure to protect against splashes and large droplets.

OSHA reiterated that surgical masks are not respirators and are not appropriate during aerosol-generating procedures.



May 11, 2020


Topic Area: Press Release


Recent Posts

Cleanliness in Hospitals: Clinical Priority and Community Perception

EVS managers and communities value cleanliness for complementary reasons: managers for safety and compliance, communities for trust and comfort.


Dana-Farber Receives $50M Gift for Planned Cancer Hospital

A $50 million grant from the Yawkey Foundation will support construction of Dana-Farber Cancer Institute’s planned 450,000-square-foot cancer hospital.


Clarinda Regional Health Center Reports Data Security Incident

On or around December 15, 2025, Clarinda learned that certain data within its network may have been accessed without authorization.


Gaps in Nurses' Environmental Cleaning Knowledge Grow Amid Rising EVS Pressures

Environmental cleaning is crucial in preventing HAIs, but when the responsibility falls to those outside of EVS teams, problems arise. 


Ground Broken on the Southern Nevada Forensic Facility

Construction on the new secure forensic psychiatric hospital is expected to be completed in 2029.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.