Control energy costs by using the new APN Series Digital Power Monitor from NK Technologies

By Healthcare Facilities Today


SAN JOSE, CA – NK Technologies introduces the APN Series Power Monitoring Sensor. The APN Series Power Monitor measures three phases of current and voltage and computes fourteen values necessary to track power usage in the RS485 Modbus RTU format. The monitor uses current transformers to measure the amperes. The line voltage connects directly to the transducer, up to 600 VAC. 

“This sensor is a big step forward from analog signal reporting watt consumption to a digital format allowing information on the system voltage, current, and power factor along with wattage,” says Philip Gregory, President, NK Technologies. As the cost of electrical power increases, the desire to use less energy also increases and the need to measure power consumption becomes a necessity, explained Gregory. 

Electrical energy is measured in watts over time. To measure watts in an alternating current circuit, the supplied voltage is compared with the current, and whether the current peaks before the voltage (leading power factor in a mostly reactive circuit) or the current peaks after the voltage (lagging power factor in a more inductive circuit), the real power is measured. 

“Electronic Smart meters” are used to measure watts, but they only provide information about the entire service consumption. To monitor individual loads or processes, watt transducers or power monitors can be installed. The purpose is to obtain information to help isolate potential problems such as phase loss or voltage sags and voltage spikes, unbalanced current phase to phase, and can help avoid utility surcharges levied for poor power factor.

The APN’s RS485 Modbus RTU format is compatible with many programmable logic controllers and fits seamlessly into industrial communications networks, both hard wired and wireless depending on the specifics of the application. The APN can be configured to accept standard 5 amp current transformer inputs or sensors producing 333mVAC proportional to the AC current of the circuit, or they can use factory matched Rogowski coil inputs. The primary circuit voltage is connected directly to the monitor for 600 VAC or lower, or through a potential transformer for monitoring circuits of higher potentials.

The APN is powered from an external supply, improving measurement accuracy of the measurement data. The APN series also provides a pulse contact to open and close as watt hours are accumulated. This feature allows for a less complex data acquisition device for applications where the need to monitor circuit voltages or the other data points is minimal.

 



January 8, 2014


Topic Area: Press Release


Recent Posts

Case Study: How NYU Langone Rebuilt for Resilience After Superstorm Sandy

Although the damage was severe, it provided a valuable opportunity for NYU Langone to assess structural vulnerabilities and increase facility resilience.


Frederick Health Hospital Faces 5 Lawsuits Following Ransomware Attack

The lawsuits accuse FHH of inadequate cybersecurity, poor breach notification and failing to protect patients from identity theft risks.


Arkansas Methodist Medical Center and Baptist Memorial Health Care to Merge

They have signed a non-binding letter of intent to complete a shared mission agreement to merge the two organizations.


Ground Broken on Intermountain Saratoga Springs Multi-Specialty Clinic

The clinic is scheduled to open and start seeing patients in the fall of 2026.


Electrical Fire Tests Resilience of Massachusetts Hospital

Signature Healthcare Brockton Hospital used opportunity to renovate key systems and components and expand facility operations.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.