Legrand Outlines Essential Changes to Lighting Control in New Florida Building Code


On December 31, 2017, Florida will transition to a new building code with updated guidelines for automatic receptacle control, electrical energy monitoring, lighting control provisions and requirements for additional efficiency package options. Changes for lighting control in the 2017 Florida Building Code – Energy Conservation, or known as the 6th edition, include regulations for automatic daylight-responsive controls, occupancy sensor controls, and exterior lighting.

Amendments to the energy conservation portion of the building code can require dense reading with code references which can be hard to follow on first look. That’s why Harold Jepsen, Vice President of Standards and Industry, Building Control Systems at Legrand has outlined the biggest changes to the lighting and power control provisions:

  1. Automatic Daylight-Responsive controls are now required for sidelight and toplight daylight zones, as opposed to the 2014 Florida Building Code which allowed manual switch controls.

 

  1. Occupancy sensor controls used for automatic lighting shut-off have been expanded to include copy/print rooms, lounges, locker rooms, and warehouse spaces on top of the other eight spaces previously required by the 2014 code.

 

  1. When unoccupied, warehouse aisles and open area lighting must now be reduced by at least 50 percent.

 

  1. Building façade and landscape lighting is required to be control independent of all other site and parking lot lighting and must turn on and off as a function of the building’s use times.

 

  1. All other lighting that is not façade and landscape must reduce its lighting by at least 30 percent either between midnight and 6 a.m.or one hour before business closing, whichever comes first.

 

  1. Automatic receptacle control provisions have expanded, now requiring spaces such as conference rooms, print/copy rooms, break rooms, classrooms, and individual work stations to automatically shut off 50 percent of the receptacles when no one is occupying those spaces.

 

  1. The new version of the code adds one more lighting specific item to its Additional Efficiency Package Options.

As a result of these changes, Florida will see a compelling leap in energy efficiency and reduction in energy use across all commercial facilities.

Florida Building Codes are uniformly adopted statewide for all local jurisdictions, and is updated, by rule, every three years to adopt the most current International Energy Conservation Code (IECC). The 2017 Florida Building Code for commercial buildings follows the 2015 IECC model energy code and, with a few amendments, including the automatic receptacle control and electrical energy monitoring provisions from ASHRAE 90.1. The code also permits ASHRAE 90.1-2013 to be followed as an alternative path of compliance.

For more information about the latest energy codes including the 2017 Florida Building Code, please visit: https://www.legrand.us/wattstopper/government/energy-codes-and-efficiency.aspx



November 17, 2017


Topic Area: Press Release


Recent Posts

Creating Compassionate Spaces in Healthcare

A new bereavement room at the Children’s Hospital of Michigan NICU aims to provide peace and privacy for families.


Study Shows Connection Between Odor and Patient Experience

A 2024 study identifies the top smells in hospital waiting rooms and how they impact the patient and visitor experience.


Boca Grande Health Clinic Opens in Florida

The clinic will offer primary and urgent care, plus expanded laboratory and imaging services.


Medical Outpatient Buildings: 4 Trends Bringing Risk, Opportunity

As healthcare delivery pivots toward outpatient settings to provide care, four trends affect healthcare systems' real estate strategies.


Building Senior Care Facilities for Harsh Temperatures

Going beyond the building code requirements is key for temperature resilience.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.