Is Dry Hydrogen Peroxide Effective in Hospitals?

New study looks at bacteria levels after cleaning with DHP


A new study published in the American Journal of Infection Control assessed the efficacy of using dry hydrogen peroxide (DHP) technology in conjunction with standard manual cleaning to reduce microbial contamination in the air and on surfaces at Sunrise Hospital and Medical Center and Sunrise Children’s Hospital, acute care facilities located in Las Vegas.

“Numerous studies show that even after manual cleaning, as many as 50 percent of surfaces remain contaminated with pathogens, including multidrug-resistant organisms,” says Jennifer Sanguinet, DrPh, FAPIC, CIC, MBA-HCM, BSIS, Principal Investigator. “As the primary investigator, I’m proud of our study results showing the effectiveness of DHP technology in reducing both air and surface microbial contamination.”

Microbial burden levels were measured from air and surface samples collected before and after technology activation during the 28-day study. Routine manual cleaning operations were continued throughout the study time frame. Surface samples included those collected from high-touch surfaces — privacy curtains, bed rails and nursing counters — and one low-touch surface — top of proximity cabinet.

When compared to the average number of bacteria present on surfaces measured before activating DHP technology, the study reported a statistically significant 96.5 percent reduction in the average number of bacteria observed in all surface samples after one day of continuous operation of the appliance and an overall reduction of 92.0 percent on sampled surfaces was being sustained by Day 28.

Samples taken on hard surfaces reflected a decrease of 94.3 percent after one day of DHP technology treatment, maintaining an 88.8 percent reduction after 28 days of continuous operation of the appliance. The highest levels of reduction were seen on harder-to-clean, soft surfaces, such as privacy curtains — 99.5 percent on day one and 96.6 percent on day 28.

Study investigators analyzed the samples by Genus ID to identify which organisms were present. The predominant organisms before DHP treatment included bacteria such as those found in normal skin flora and Acinetobacter lwoffii, a pathogenic bacterium linked to infections that can survive for long periods on surfaces. DHP was effective in the reduction of predominant Gram-negative rod throughout the experiment, and Acinetobacter lwoffii was no longer identified as the primary microorganism present in samples taken from surfaces after one week of continuous operation of the DHP technology.



April 27, 2021


Topic Area: Infection Control


Recent Posts

Designing for Senior Care Communities Means Designing for Everyone

No spaces can be designed for just one person, designers need to think about everyone who will occupy the space.


Harlem Hospital Legionnaires' Outbreak Highlights Cooling Tower Risks

Seven deaths linked to the cooling towers underscore the need for stricter water system monitoring and preventive maintenance in healthcare settings.


WelbeHealth Opens Two New Centers in California

The two new centers are located in Elk Grove and San Bernardino.


Healthcare Security: To Arm Or Not To Arm?

Deciding whether or not to hire armed security personnel requires that managers understand a range of critical considerations.


False Alarm at Kansas Hospital Highlights Importance of Alarm System Reliability

After a two-hour search of the hospital and nearby medical facilities, no threat was found.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.