Major Revision to Drinking Water Treatment Standard Allows UV-LED Technology to Treat Microorganisms


The joint committee of experts that maintains an NSF International drinking water treatment standard has recently updated it to allow a more efficient method of treating microorganisms in drinking water. The revision to NSF/ANSI 55: Ultraviolet Microbiological Water Treatment Systems establishes new criteria for use of UV-LED technology for microbial reduction and provides a new test method to certify manufacturer claims. 

Treatment systems covered by the standard use ultraviolet light to inactivate or kill bacteria, viruses and cysts in microbiologically unsafe water (Class A systems) or to reduce the amount of non-disease-causing bacteria in disinfected drinking water (Class B systems).

“This is a significant update to the drinking water treatment standard. While non-disinfecting LEDs are found in everyday applications such as lighting fixtures and consumer electronics, this use of ultraviolet LED technology is very different. Lab testing shows that ultraviolet LED technology is effective at reducing bacteria and other types of microorganisms in drinking water,” said Jessica Evans, Director of Standards Development at NSF International. NSF is accredited by the American National Standards Institute (ANSI) to develop standards using its consensus-based process with a balanced group of stakeholders.

Originally developed in 1991, NSF/ANSI 55’s scope was limited to low-pressure ultraviolet (UV) radiation systems using low-pressure mercury bulbs, which was the only technology available in the marketplace at the time.

In 2014, the Drinking Water Treatment Units Joint Committee responsible for the NSF/ANSI standard began developing a protocol to address newer alternate UV technologies.

After considering several options, a task group recommended the approach of running a direct log-reduction test with an organism that would represent an entire class of organisms.

The task group concluded that the virus Q-beta is an acceptable surrogate to Rotavirus and the test method performs appropriately. This holds true at both ends of the UV wavelength range examined (254 nm to 285 nm). Testing with Q-beta directly is also a simpler, more consistent and less expensive protocol than having to conduct the collimated beam study required in the original protocol.

The existing protocol for current systems will remain in NSF/ANSI 55 for at least five years. Manufacturers will have the option to evaluate their product to the new test method or the older test method defined within the standard. For devices with wavelengths other than 254 nm, the new method using Q-beta would be required and would have the following criteria:

  • 4-log reduction of Q-beta at the alarm set point for Class A devices
  • 1.5-log reduction of Q-beta for Class B with UV source irradiance at 70% normal output or 2.14-log reduction with UV source irradiance at 100% normal output

NSF/ANSI 55 was developed following the American National Standards Institute (ANSI) process designed to ensure openness, balance, consensus and due process for all stakeholders. The Drinking Water Treatment Units Joint Committee is comprised of stakeholders representing consumers, the water industry, and state and federal health and environmental agencies in the U.S. and Canada. The joint committee is comprised of 108 people (including 28 voting members, plus observers who offer input and expertise during the standard development process) and is facilitated by NSF International’s standards development group.

As the final step in the standards development process, NSF/ANSI 55 was ratified by NSF’s Council of Public Health Consultants, which includes representatives from the U.S. EPA and the Centers for Disease Control and Prevention (CDC).



November 27, 2019


Topic Area: Press Release


Recent Posts

Case Study: How NYU Langone Rebuilt for Resilience After Superstorm Sandy

Although the damage was severe, it provided a valuable opportunity for NYU Langone to assess structural vulnerabilities and increase facility resilience.


Frederick Health Hospital Faces 5 Lawsuits Following Ransomware Attack

The lawsuits accuse FHH of inadequate cybersecurity, poor breach notification and failing to protect patients from identity theft risks.


Arkansas Methodist Medical Center and Baptist Memorial Health Care to Merge

They have signed a non-binding letter of intent to complete a shared mission agreement to merge the two organizations.


Ground Broken on Intermountain Saratoga Springs Multi-Specialty Clinic

The clinic is scheduled to open and start seeing patients in the fall of 2026.


Electrical Fire Tests Resilience of Massachusetts Hospital

Signature Healthcare Brockton Hospital used opportunity to renovate key systems and components and expand facility operations.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.