New COIN Specific Application Sprinkler Offers 16’ x 16’ Coverage for Combustible Interstitial Spaces


 The Viking Corporation, a global leader in fire protection and life safety systems, has introduced a new quick response specific application upright sprinkler for combustible interstitial (concealed) spaces, such as those found between floors and for low-pitch attics with roof pitches up to and including 2/12. With a coverage area up to 16’ x 16’, and a maximum height of 60”, the new 5.6K COIN® (COmbustible INterstitial) Model VK950 features a glass bulb operating element and special deflector that delivers the operation speed and broad distribution pattern required in shallow combustible concealed spaces. COIN® sprinklers are designed to protect areas constructed of wood truss, non-combustible bar joist, solid wood joists, or composite wood joists.

COIN® sprinklers are cULus Listed for use in specific light hazard combustible as well as non-combustible concealed spaces requiring sprinkler protection as outlined in NFPA 13, and can be installed in both CPVC and steel wet pipe sprinkler systems. When using steel pipe, they can be also be used in dry sprinkler systems.

The new Model VK950 has a 200°F (93°C) temperature rating and features a ½ in (15 mm) NPT thread size. In addition to the standard brass finish, the sprinkler is available with an Electroless Nickel PTFE (ENT) plating for corrosion resistance.

Viking also offers an extensive line of specific application Attic sprinklers suited for both wet and dry pipe systems in combustible and non-combustible sloped attic spaces.

 



January 11, 2017


Topic Area: Press Release


Recent Posts

Building Sustainable Healthcare for an Aging Population

Traditional responses — building more primary and secondary care facilities — are no longer sustainable.


Froedtert ThedaCare Announces Opening of ThedaCare Medical Center-Oshkosh

The organization broke ground on the health campus in March 2024.


Touchmark Acquires The Hacienda at Georgetown Senior Living Facility

The facility will now be known as Touchmark at Georgetown.


Contaminants Under Foot: A Closer Look at Patient Room Floors

So-called dust bunnies on hospital room floors contain dust particles that turn out to be the major source of the bacteria humans breathe.


Power Outages Largely Driven by Extreme Weather Events

Almost half of power outages in the United States were caused by extreme weather events.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.