Preventing Bacteria in Ice, Water and Beverage Equipment

Water management and safety plans are just one step to prevent bacteria outbreaks ice machines, drinking fountains, and beverage dispensers

By Mackenna Moralez, Assistant Editor


Ensuring patient comfort is a top priority for hospitals and other healthcare facilities, and iced drinks and ice chips are common offerings to achieve this goal. But failed routine maintenance of ice machines in these facilities can cause the spread of bacteria such as Legionella. It is crucial that facility managers develop and implement water management and safety plans to prevent an outbreak. In this roundtable, Healthcare Facilities Today asked experts about the most effective steps for maintaining quality water and preventing the formation of Legionella in ice machines.

What steps can managers take to maintain quality water and prevent bacteria growth in ice machines?

The best approach is to maintain the systems in accordance with the manufacturer’s operating manual, which might include the following:

  • Clean and sanitize ice machines, drinking fountains, and beverage dispensers every six months according to manufacturer instructions.
  • Clean and sanitize equipment that has been repaired before placing it back in service.
  • Maintain associated filters and water treatment devices connected to the machine in accordance with manufacture instructions.
  • Perform testing of ice machines, drinking fountains, and beverage dispensers for validating an effective water management program prior to removal from service for cleaning and sanitization.
  • Maintain testing and maintenance documentation.

As with any operational management activity, it is crucial for facility managers to develop and implement a water management and safety plan for their facilities as their operating guideline and establish an operating rhythm to adhere to that plan.

— Cem Candir, chief executive officer, Chemstar Water

To prevent the risk of bacteria in ice machines, the best solution is also to use filters and to regularly sample the produced ice. We also recommend the installation of a 0.2 µm filter after the ice machine has been cleaned and disinfected.

— Professor Philippe Hartemann on behalf of AquaTools



November 22, 2021


Topic Area: Infection Control


Recent Posts

Healthcare Security: To Arm Or Not To Arm?

Deciding whether or not to hire armed security personnel requires that managers understand a range of critical considerations.


False Alarm at Kansas Hospital Highlights Importance of Alarm System Reliability

After a two-hour search of the hospital and nearby medical facilities, no threat was found.


Integrated Oncology Network Caught Up in Data Breach

The network first learned of the incident on April 11, 2025.


ISSA Introduces Healthcare Platform to Advance Safer, Cleaner Patient Environments

This new resource integrates training, research and cross-sector collaboration to raise care standards and improve patient outcomes.


Third-Party Tracking Settlement is a Compliance Wake-Up Call for Healthcare Facilities Managers

Mount Sinai Health System agrees to a $5.3 million settlement to resolve claims it improperly shared patient data with Facebook through tracking tools.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.