Spirax Sarco evolves RIM10 to RIM20


 Spirax Sarco USA, a provider in products and service for steam system management, announces the evolution of the RIM10 to RIM20 Rotor Insertion Flowmeter. The RIM20 utilizes a common electronics platform that is now available in all the new 20 Series Meters to improve reliability and ease of use across the product line.

The RIM20 provides the same great features and benefits as the RIM10 utilizing a SMART multivariable electronics for measurement of mass or volumetric flow, density, temperature and pressure in one instrument. Typical applications include measurement of steam and natural gas flows for fiscal or load control and heat flow calculations for chilled, hot water and a variety of other liquids and gases in line sizes from 3 to 80 in.

Hot-tappability makes possible installation and service without process shutdown. The RIM20 produces a negligible pressure drop, reducing energy and operation costs.

The RIM20 low-mass rotor design is fabricated from a single solid block of stainless steel, with no welded joints. There are six field-installable cartridges with different turbine pitches with NIST traceability. This field configuration versatility, plus a wide 25:1 turndown, enables the flowmeter to match flow rates precisely.

 Further information can be found at www.spiraxsarco.com/global/us.

 



July 7, 2016


Topic Area: Press Release


Recent Posts

Harris Health to Build New Freestanding Cancer Center

The center is planned to open in 2029, following the opening of the new O'Quinn Hospital along the North Loop at Lockwood.


Inland Empire Health Plan Opens Expanded San Bernardino Community Wellness Center

The new 33,000-square-foot center is nearly three times the size of the original location off Second Street.


Rethinking Parking Lot Design at Irvine Heritage Medical Plaza

A new solar installation shows how healthcare facilities can improve parking amenities while boosting energy savings


Repurposing Healthcare Spaces: 5 Critical Questions

Done well, converting existing spaces can trim upfront project costs by up to 40 percent, compared with ground-up construction


Disinfectant Contact Time: The Case for Biofilm Disruption

Contact time, while essential for compliance, does not reliably predict microbial reduction on actual healthcare surfaces.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.