A new study from the University of California, Los Angeles (UCLA) Santa Monica Medical Center found that a “high-touch wipe down” protocol using Clorox Healthcare Bleach Germicidal Wipes to disinfect surfaces in patient rooms in a medical oncology unit reduced C. difficile infections rates per 10,000 patient days from 14.99 the year prior, to zero for a six-month period and helped achieve significant sustained reductions in infection rates. 

The trial was conducted in an inpatient, 26-bed medical oncology unit where despite adherence to UCLA’s policy for early identification of C. difficile, CDI rates had remained above the national median. A nurse-driven “high-touch wipe down” protocol was initiated in February 2015 with the goal of reducing CDI rates by 50% within six months.

Canisters of Clorox Healthcare Bleach Germicidal Wipes were placed in every patient room and at nursing stations and used by nurses and care partners to wipe down high-touch surfaces – including the bed frame, call light, doorknobs, countertops, side table, nightstand, monitor cables, and work stations – once a shift for all patients and twice a shift for neutropenic patients, patients with abnormally low level of neutrophils, a common type of white blood cell important to fighting off infections, particularly those caused by bacteria like C. difficile. The intervention also included employee education. Baseline knowledge of C. difficile prevention was assessed with a pre-survey, followed by a tailored education plan to improve staff understanding of the enhanced disinfecting protocol. Education was provided via informational flyers and trainings during team huddles, staff meetings and annual skills labs and measured with a post-training test.

The results far exceeded expectations. From February to July 2015, the rate of CDIs per 10,000 patient days decreased from 14.99 in 2014, to zero. In 2016, just 6.1 cases per 10,000 patient days were reported, and the most current data from 2017 showed a further decrease to 3.4 cases per 10,000 patient days. 

 Due to its sus­tained success reducing infection rates among vulnerable oncology patients, the simple and inexpen­sive, but highly effective “high-touch wipe down” protocolhas since been implemented hospital wide. According to Maria Quirch, BSN, RN, ONC, Pattie Jakel, MN, RN, AOCN and Laura Alfonso, BSN, RN, ONC, the success of the protocol was recognized by the chief nursing officer and transformational lead­ership shared-governance Magnet council as a nursing best practice and key strategy for fiscal year 2017-2018.



February 21, 2018


Topic Area: Press Release


Recent Posts

Gaps in Nurses' Environmental Cleaning Knowledge Grow Amid Rising EVS Pressures

Environmental cleaning is crucial in preventing HAIs, but when the responsibility falls to those outside of EVS teams, problems arise. 


Ground Broken on the Southern Nevada Forensic Facility

Construction on the new secure forensic psychiatric hospital is expected to be completed in 2029.


Jackson Hospital Falls Victim to Third-Party Cybersecurity Incident

Jackson Hospital has no evidence that any personal information has been or will be used for identity theft as a direct result of this incident.


Making Healthcare Lighting Retrofits Work

Effective operational planning determines whether a retrofit project improves a facility or creates new problems.


Stadium Design is Reshaping Healthcare Facilities

Hospitals are turning to the sports industry for innovative ways to support healing and improve the patient experience.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.