Preventing Pipework Failure in Hospitals


 Pipework failure of air conditioning systems caused by corrosion is a risk in every big building. Especially in hospitals, failures may lead to shutdowns of wards or even to cancellations of surgeries. In order to prevent these unpredictable shutdowns, Hamilton Bonaduz AG offers the VisiFerm DO Arc and the Conducell 4USF Arc sensors for monitoring dissolved oxygen and conductivity in the water loop.

An increased level of dissolved oxygen indicates that oxygen has entered the system through a possible leak, poor installation or bad maintenance. VisiFerm DO Arc, based on the luminescence measurement principle, convinces with its reliable dissolved oxygen measurement down to ppb levels, fast response times and easy maintenance. Compared to conventional amperometric sensors, it is flow independent and starts up quickly. In this way, the constant monitoring of dissolved oxygen in hot and cold water systems helps to react quickly and to keep the pipework in good shape.

Additionally, corrosion inhibitors in the cooling water increase the protection level of the air conditioning systems. Since an insufficient amount of corrosion inhibitors easily leads to corrosion of the pipeline, valves and heat exchangers, a simultaneous conductivity measurement is needed to maintain a proper level. Insufficient corrosion inhibitor levels lead to low conductivity values, whereas very high conductivity values indicate a waste of resources. The Conducell 4USF Arc sensor with its EHEDG certified design measures conductivity precisely and dependably.

Both sensors use the Arc technology, i.e. the functionality of a traditional transmitter is replaced by a micro transmitter within the sensor head. In this way, the data are processed in the head and the sensors communicate directly with the process control system, including sensor diagnostics. For best monitoring results the sensors are installed in the main engine room of the air conditioning systems, where they are permanently exposed to the circulating water. For transmission and evaluation of the collected data, Hamilton cooperates with Midland Corrosion Services Ltd. / Hevasure, UK. The sensors meet the company’s needs and enable them to plan the maintenance of the air conditioning systems in advance. Thus unplanned and unnecessary downtimes can be avoided and the availability of the systems can be increased.

For more information, visit www.hamiltoncompany.com.

 




 

   


October 25, 2016


Topic Area: Press Release


Recent Posts

Mature Dry Surface Biofilm Presents a Problem for Candida Auris

Multiple methods are described in the literature, but no consensus has been reached for disinfection efficacy tests against biofilms.


Sutter Health's Arden Care Center Officially Opens

With an adaptive reuse of an underutilized office building, the 70,000 square-foot facility was renovated to meet current healthcare standards.


Insight Hospital and Medical Center Falls to Data Breach

The investigation determined that an unauthorized individual accessed the network between August 22, 2025, and September 11, 2025.


The High Cost of Healthcare Violence

As workplace violence increases, healthcare facilities face mounting financial and operational disruptions- prompting legislative action.


EVS Teams Can Improve Patient Experience in Emergency Departments

A report confirmed that cleanliness of the ED was the third most impactful element on patient experience surveys.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.