Xtralis VESDA aspirating smoke detectors provide fire prevention for the new Abu Dhabi Airport Midfield Terminal


Xtralis VESDA VLS aspirating smoke detectors will provide fire prevention at the new Abu Dhabi International Airport Midfield Terminal Building (MTB), scheduled to open in 2017. The MTB will be the largest in the Emirate of Abu Dhabi, and one of the region’s most architecturally impressive structures. Xtralis VESDA & VESDA-E aspirating smoke detectors (ASD) now protect many of the United Arab Emirates super structures, including the Burj Khalifa, Emirates Palace Hotel, and Dubai & Abu Dhabi International Airports. Xtralis VESDA brand is the world’s most dominant aspirating smoke detector, with greater than 65 percent ASD worldwide market share, according to estimates from IHS Technology.

The new Midfield Terminal Complex (MTC) will have 700,000 sq-m of internal space for a passenger terminal (MTB), cargo facility, and restaurant and retail space. The size of the MTC is so impressive that it will be visible from 1.5 km away. The facility can accommodate 8,500 passengers per hour and up to 30 million per year. The central space of the terminal building could hold three full-sized football (soccer) pitches and features a ceiling 52 m tall at its highest point, taller than the Emirates Palace and will include 28,000 sq-m of retail outlets and restaurants.

Chief among the challenges with protecting the MTB was the massive open space where smoke will be diluted, an effect compounded by air-conditioning systems. VESDA’s early and reliable detection combined with the VLS capability of monitoring the protected space by sectors were key factors that resulted in the selection of the Xtralis solution. Additionally, temperatures in the terminal could range from hot to cold, depending on the weather, and VESDA was the only detector that could ensure early and reliable detection under these conditions. Xtralis provides comprehensive safety and security solutions for airports, including smoke and gas detection, perimeter security, and intrusion detection. To learn more, visit www.xtralis.com/airports.

The VESDA LaserScanner (VLS) is similar to the VESDA LaserPlus (VLP) detector, but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four sectors (pipes). This configuration enables a single zone to be divided into four separate sectors, for example, distinguishing between separate voids within a room. The VLS draws air from all sectors in use. If the smoke level reaches the Adaptive Scan Threshold, the VLS performs a Fast Scan of each pipe to identify which pipe is carrying smoke. If more than one pipe is transporting smoke, the sector with the highest smoke concentration is scanned first. Once Fast Scan is completed and the sector with the highest smoke concentration is identified, the VLS continues to closely monitor all four sectors (pipes) to monitor fire growth and maintain full protection of the area. There are four alarm levels (Alert, Action, Fire 1 and Fire 2) for each sector (pipe) and the sensitivity for each alarm level can be set to ensure the optimum alarm thresholds are applied for each sector. Learn more about the entire line of VESDA detectors, visit www.xtralis.com/VESDA.



January 11, 2016


Topic Area: Press Release


Recent Posts

Mattresses Require Strict Care to Prevent Spread of Infections

Poor cleaning and disinfection techniques contribute to the persistent contamination of patient mattresses.


Gardner Health Services Opens Alum Rock Health Center

The 10,080-square-foot facility provides essential medical, dental, mental and chiropractic services to the Mayfair and East San José neighborhoods.


The Children's Center of Hamden Reports Data Security Incident

The incident was detected on December 28, 2024.


Designing for Senior Care Communities Means Designing for Everyone

No spaces can be designed for just one person, designers need to think about everyone who will occupy the space.


Harlem Hospital Legionnaires' Outbreak Highlights Cooling Tower Risks

Seven deaths linked to the cooling towers underscore the need for stricter water system monitoring and preventive maintenance in healthcare settings.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.