Schaffner introduces Sine Wave filters for VFD motor drives


The new lineup of Sine Wave filters from Schaffner EMC eliminate premature motor damage caused by high dv/dt, overvoltages, cable ringing, motor overheating and eddy current losses caused by Variable Frequency Drives (VFD).  Suitable for motor frequencies up to 600Hz, this proven technology converts the rectangular PWM output voltage of motor drives into a smooth sine wave with low residual ripple.  In addition to elongating service life of expensive high speed motors, Schaffner Sine Wave filters can improve bearing life by eliminating circulating bearing currents.  Typical applications include high-speed spindles, textile machinery, lasers, military appliances (400Hz), HVAC applications, pumps, ventilators, conveyors, compressors, elevators, cranes, step-up transformers, motor drives with multiple motors, and motor drives with long motor cables.

A full product line is available to accommodate a wide range of switching kHZ, and voltage ratings up to 690vac.  Motor frequency can manage typically 60hz equipment and higher speed 600hz, with application engineered design for even higher frequencies.  Model FN5020 and FN5040 Sine Wave filters are offered as open and enclosed.

Available for motors up to 200 HP (UL508C) over 200 HP to 800 HP (UL pending). Schaffner  Sine Wave filters are easily installed and provide immediate results.

 



June 26, 2015


Topic Area: Press Release


Recent Posts

What Managers Miss in Small and Mid-Sized Cooling Units

The assumption is that small cooling units are fine. That assumption is costing facilities more than most owners and managers realize.


Preparing Healthcare Facilities for Cockroach Risks

Here’s what healthcare facilities managers should inspect and address after severe weather to prevent pest problems.


The Medical College of Wisconsin Breaks Ground on Student Housing Complex

The four-story apartment complex will include 266 units of various sizes.


A Shift in Healthcare Facilities Management

Healthcare facilities leaders who embrace a mindset change will be better prepared for the future.


Trauma-Informed Design Transforms Boston Homeless Shelter

Case study: A comprehensive renovation of St. Francis House makes use of trauma-informed design, infrastructure upgrades and operational improvements.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.